The K6516 Multifunction Installation Tester are advanced multifunction testers performing 12 separate test functions which are required for SANS 0142 and IEC 61557-10. The multifunction’s include Insulation with PI and DAR, continuity, earth loop impedance, RCD testing, prospective short circuit, prospective fault current, earth resistance, AC Voltage, frequency, phase rotation, SPD (varistor) and PAT (portable appliance testing). The meters can store a maximum of 1000 measured results and the K6516 downloaded via a K8212- USB adaptor. The K6516’s are software driven and guides the user through the colour graphic display, making the meter very user friendly. The K6516’s come supplied with a remote test lead for hands free testing. The ATT (anti trip technology) with 2 and 3 wire for no trip Loop L-PE on all RCD’s. With 2 wire only can test with no neutral (eg 3-phase motors).
Multifunction Testers
Multifunction Installation Tester
Availability:
Out of stock
R42,866.25
- Installation 4 ranges 100/250/500/1000V, automatic discharge of capacitance, Polarization Index (PI) and Dielectric Absorption ratio (DAR)
- Loop Impedance High Test current range of 2Ω with 0,001Ω resolution
- RCD Type AC, A, F, B (general & selective) EV (electric vehicle) and variable RCD’s, single and auto test, ramp test and contact voltage
- Earth Resistance test 2 & 3 wires with all accessories
- ACV Trms Voltage measurements 2V to 600V, mains frequency
- Continuity test at 200mA or15mA with selectable buzzer for fast judgment
- Phase rotation on 3-phase lines with clear indication of the sequence on the display
- SPD (Varistor) Surge protection device test, for SPD that uses varistor
- PAT- Portable Appliance Tester function for insulation and continuity
- Connectivity: K6516 via USB (to PC)
Out of stock
Specifications
Function | Range | Resolution | Accuracy |
Continuity | 20.00/200.0/2000Ω | 0.01Ω | ± (2% + 8 Digits) |
Insulation resistance | 100/250/500/1000V | 2.000/20.00/200.0/2000MΩ | ± (2% + 6 Digits) |
Loop range | 20.00/200.0/2000Ω | 0.01Ω | ± (3% + 4 Digits) |
RCD | x 5, x 1, x 1/2, auto ramp mA | ± (1% + 2ms) | 10/30/50/100/200/500/1000mA |
Measuring range | 2000ms | ± (1% + 2ms) | |
Voltage measurement | 300.0/600V | ± (2% + 4 Digits) | |
Earth resistance | 20.00/200.0/2000Ω | ± (2% + 0.08Ω) | |
Short circuit current | >200mA | ||
Rated current | 1 – 1.2mA | ||
Loop Impedance | L-PE, L-PE(ATT), L-N,L-L | ||
PSC/PFC | Derived from Loop and Voltage measurement | ||
Test current | 6A/20mS | ||
Phase angle | 0° to 180° | ||
Frequency response | 45-65Hz | ||
PC Interface | Yes | ||
Display | Colour LCS 3.5 in dot matrix | ||
Memory | 1000 Test results | ||
Back light | Yes | ||
Enclosure | Moulded case IP54 | ||
Low battery indication | Yes | ||
Power source | 8 x LR6 | ||
Weight | 1300g | ||
Dimensions | 235 x 136 x 114mm | ||
Safety specs | IEC61010-1 CatIV 300V |