The K4106 is a Earth Resistivity and Resistance Tester equipped with a microcomputer and can measure earth resistances and calculate earth resistivity’s (ρ), using the “Wenner” 4 pole method. This instrument is ideal for Earth measurements also in large Earthing systems because it uses a considerable test current of 80mA(max) yielding a high resolution of 1mΩ on 2Ω range. The Earth Resistivity measurement is useful for soil surveys to establish the optimum earth electrode system design and site, to avoid extra cost of reworking electrode installations. It can also be suitable for geological investigations.
Earth Leakage & Resistance Testers
Earth Resistivity and Resistance Tester
Availability:
Out of stock
R40,451.25
- High test current up to 80mA yielding resolution of 0.001Ω on 2Ω range.
- Advanced Filtering method (based on FFT Fast Fourier Transform) reduces noise interference for obtaining stable measurements.
- Earth resistance measurement with 4, 3 and 2 wires
- Earth resistivity tester (ρ) using 4 pole Wenner method
- 800 Data storage points
- Test current frequency in four bands of 94 / 105 / 111 / 128Hz
- Earth (Ground) Resistance 200kΩ
- Earth Soil Resistivity 200kΩ
- “Zero adjust” the Residual Resistance (Rk)
- Soil Earth Resistivity is automatically calculated
- Distance set within a range of 1.0 to 30.0m at 0.1m steps
- Several sub-results and parameters can be shown on the display: Resistance of the Auxiliary Earth Spikes, Frequency of Test Current, Voltage and Frequency of Interference (noise), Residual Resistance Rk, etc.
- Memory, recall and download – results via USB adaptor
- Warning indication of noise & high resistance of auxiliary earth spikes
- Robust design with IP54 protection
Out of stock
Specifications
Function | Range | Resolution | Accuracy |
Earth resistance | 2/20/200/2000/20K/200KΩ | 0.001Ω | ± (2%+ 0.03Ω) |
Earth resistivity ᴩ | 2/20/200/2000/20K/200KΩ | 0.1Ω m to 1Ω m | Depends on Rg measurement |
Earth voltage | 0 – 200V | 0.1V | ± (2% + 2 Digits) |
Frequency | 40-500Hz | 0.1Hz | ± (1% + 2 Digits) |
Test current frequency | 94/105/111/128Hz | ||
PC interface | Yes | ||
Display | LCD Display | ||
Memory | 800 readings | ||
Back light | Yes | ||
Enclosure | Moulded case IP54 | ||
Low battery indication | Yes | ||
Power source | 8 x R6P | ||
Weight | 900g | ||
Dimensions | 167 x 185 x 89mm | ||
Safety specs | IEC61010-1 CatIII 300V |
Downloads
Download “K4106 Instruction Manual”
K4106-Instruction-Manual.pdf – Downloaded 1 time – 9.45 MBAccessories
Instruction Manual